Physical and Mechanical Properties
Item according to DIN EN 1561 |
Measure |
Unit |
EN-GJL-150 |
EN-GJL-200 |
EN-GJL-250 |
EN-GJL-300 |
EN-GJL-350 |
EN-JL 1020 |
EN-JL 1030 |
EN-JL 1040 |
EN-JL 1050 |
EN-JL 1060 |
|||
Tensile Strength |
Rm |
MPA |
150-250 |
200-300 |
250-350 |
300-400 |
350-450 |
0.1% Yield Strength |
Rp0,1 |
MPA |
98-165 |
130-195 |
165-228 |
195-260 |
228-285 |
Elongation Strength |
A |
% |
0,3 – 0,8 |
0,3 – 0,8 |
0,3 – 0,8 |
0,3 – 0,8 |
0,3 – 0,8 |
Compressive Strength |
σdB |
MPa |
600 |
720 |
840 |
960 |
1080 |
0,1% Compressive Strength |
σd0,1 |
MPa |
195 |
260 |
325 |
390 |
455 |
Flexural Strength |
σbB |
MPa |
250 |
290 |
340 |
390 |
490 |
Schuifspanning |
σaB |
MPa |
170 |
230 |
290 |
345 |
400 |
Shear Stress |
TtB |
MPa |
170 |
230 |
290 |
345 |
400 |
Modules of elasticity |
E |
GPa |
78 – 103 |
88 – 113 |
103 – 118 |
108 – 137 |
123 – 143 |
Poisson number |
v |
– |
0,26 |
0,26 |
0,26 |
0,26 |
0,26 |
Brinell hardness |
|
HB |
160 – 190 |
180 – 220 |
190 – 230 |
200 – 240 |
210 – 250 |
Ductility |
σbW |
MPa |
70 |
90 |
120 |
140 |
145 |
Tension and pressure change |
σzdW |
MPa |
40 |
50 |
60 |
75 |
85 |
Breaking Strength |
Klc |
N/mm3/2 |
320 |
400 |
480 |
560 |
650 |
Density |
|
g/cm3 |
7,10 |
7,15 |
7,20 |
7,25 |
7,30 |